Weblims     OWA     Home     Contact Us    

Actlabs
Back to Home


25 of 150    Prev    Next     

1E2 - Aqua Regia - ICP

0.5 g of sample is digested with aqua regia for 2 hours at 95 °C. The sample is cooled and then diluted with deionized water. The samples are then analyzed using a Varian ICP for the 35 element suite. QC for the digestion is 15% for each batch, 2 method reagent blanks, 6 in-house controls, 8 sample duplicates and 5 certified reference materials. An additional 20% QC is performed as part of the instrumental analysis to ensure quality in the areas of instrumental drift.

 

Code 1E2 Elements and Detection Limits (ppm)

Element

Detection Limit

Upper Limit

Element

Detection Limit

Upper Limit

Element

Detection Limit

Upper Limit

Ag

0.2

100

Fe

0.01%

50%

Sc

0.1

-

Al

0.01%

10*

K

0.01%

10%

Sn

5

-

As

3

10,000

La

1

-

Sr

1

-

B

5

-

Mg

0.01%

25%

Te

1

500

Ba

1

-

Mn

1

100,000

Ti

0.01%

20%

Be

1

1000

Mo

2

10,000

Tl

2

10,000

Bi

2

10000

Na

0.001%

10%

V

1

10,000

Ca

0.01%

10%

Ni

1

10,000

W

1

10,000

Cd

0.2

2,000

P

0.001%

10%

Y

1

1000

Co

1

10,000

Pb

2

5,000

Zn

1

10,000

Cr

2

-

S

0.001%

20%

Zr

1

-

Cu

1

10,000

Sb

5

-

 

Notes:   

Extraction of each element by Aqua Regia Digestion is dependent on mineralogy.

Assays are recommended for values which exceed the upper limits.

 


Activation Laboratories Ltd. | 41 Bittern Street, Ancaster, Ontario, L9G 4V5, Canada | TF: +1.888.228.5227