2D - Vegetation Ash - ICP/MS

Vegetation samples are ashed at 475°C over a 36 hour period. A proprietary acid digestion is used on the ash. Digested ash samples are diluted and analyzed by Perkin Elmer Sciex ELAN 6000, 6100 or 9000 ICP/MS.  A matrix blank and digested blank are each run every 35 samples.  Two digested standards are run every 35 samples. Instrument is recalibrated every 70 samples. Duplicates are digested and analyzed every 14 samples. Results are reported on an ash weight basis.  If Au, Pd, Pt are required please use Code 2E.

 

Required Preparation: Code B3 (drying and ashing at 475°C in dedicated kilns)

 

Code 2D (Vegetation Ash-ICP/MS) Elements and Detection Limits (ppm)

Element

Detection Limit

Element

Detection Limit

Element

Detection Limit

Element

Detection Limit

Ag

0.2

Er

0.001

Mo

0.1

Ta

0.001

Al

2

Eu

0.001

Na

0.01%

Tb

0.001

As

1

Fe

0.01%

Nb

0.005

Te

0.01

B

5

Ga

0.1

Nd

0.002

Th

0.001

Ba

3

Gd

0.01

Ni

5

Ti

1

Be

0.005

Ge

0.1

Pb

0.1

Tl

0.001

Bi

0.05

Hf

0.01

Pr

0.002

Tm

0.001

Ca

0.1%

Ho

0.001

Rb

0.01

U

0.001

Cd

0.01

In

1 ppb

Re

0.1 ppb

V

1

Ce

0.01

K

0.01%

Sb

0.02

W

0.5

Co

0.01

La

0.002

Sc

0.5

Y

0.001

Cr

1

Li

0.5

Se

1

Yb

0.001

Cs

0.001

Lu

0.001

Si

0.2%

Zn

1

Cu

0.2

Mg

0.01%

Sm

0.001

Zr

0.5

Dy

0.001

Mn

0.1

Sr

0.1


Activation Laboratories Ltd. | 41 Bittern Street, Ancaster, Ontario, L9G 4V5, Canada | TF: +1.888.228.5227